Cloridox-GMP The Cloridox-GMP Sterilization System is portable in design and is comprised of a gas generation section and a sensing/electronic section. These are used in conjunction with an operator control and monitoring system. The PLC system controls and monitors pressures, temperatures, relative humidity, and chlorine dioxide gas concentration during the operating cycle. A sophisticated operator interface system allows for easy cycle development and cycle selection. A documented run record is produced which includes all of the critical process parameters. An optional steam inject module delivers steam to raise relative humidity to within a specified range. |
|
Dimensions •Dimensions: 43" Wide x 62" High x 28" Deep•Weight: 600 lbs. Utility Requirements Utility Requirements at Point-of-Use•100 - 240 VAC, 5 amp, single phase •20 psi steam (for optional Steam Injector) •15 cfm, negative pressure exhaust Utility Requirements at Consummable Changeout Station •60-100 psi, 25 cfm, clean, dry compressed air •15 cfm, negative pressure exhaust •100 - 240 VAC, 5 amp, single phase |
|
Cloridox-B The non-GMP version of the Cloridox-GMP is available as a low cost CD generation system for applications that don't require full GMP systems. It is especially suited for room decontamination. |
|
Dimensions •Dimensions: 43" Wide x 62" High x 28" Deep•Weight: 600 lbs. Utility Requirements Utility Requirements at Point-of-Use•100 - 240 VAC, 5 amp, single phase •20 psi steam (for optional Steam Injector) •15 cfm, negative pressure exhaust Utility Requirements at Consummable Changeout Station •60-100 psi, 25 cfm, clean, dry compressed air •15 cfm, negative pressure exhaust •100 - 240 VAC, 5 amp, single phase |
|
Cloridox-DS The
Cloridox-DS Sterilization System can completely control a cycle for a wide
range of research and production applications within a given chamber. The
typical chlorine dioxide gas generating system consists of the following
modules:
|
|
Dimensions •Dimensions: 70" Wide x 70" High x 22" Deep•Weight: 1250 lbs.
Utility
Requirements •15 cfm, negative pressure exhaust •Power requirements configurable for the following voltages: •100 +/- 10%VAC, 15 amp, single phase •120 +/- 10%VAC, 15 amp, single phase •220 +/- 10%VAC, 10 amp, single phase •230 +/- 10%VAC, 10 amp, single phase •240 +/- 10%VAC, 10 amp, single phase •20 psi steam (for optional Steam Injector)
Available Options •Adjustable Length Steam Inject Module - #1005 •Vacuum Sensor Module - #1006 •Photometer Calibration Filter Set - #1007 |
For assistance call 1- 800-801-9934 and ask for
Andrea, Renata, Ed, Shlomo, or Chuck
Contact Us
Find an autoclave or sterilizer that will sterilize all instruments. COX dry heat sterilizer, Pelton and Crane OCM, OCR; Distributors of Sterilizers & Autoclaves. |