Eschmann SES Little Sister Autoclaves
Little Sister 3 | Little Sister 5 | Little Sister Washer | Little Sister Quickvac
Description: The Little Sister 3 is a downward displacement autoclave suitable for dentists, doctors in general practice, chiropodists, veterinary surgeons and other practitioners for the sterilization of solid instruments and utensils for immediate use. Safety: Autoclaves are widely acknowledged
as the best way to sterilize equipment and instruments efficiently
and effectively and achieve a standard of sterilization that cannot
be equaled. Simple Use: Microprocessor controlled preventing operator error. The hygienic 'touch panel' controls activate a choice of cycles provided by the Little Sister 3. Select the appropriate temperature option for the load type, and with one touch it's in operation. It is so simple, anyone can work it. Reassurance: The Little Sister 3 autoclave has a printer which enables a permanent record of each procedure to be kept. This means reassurance for both you and your patient. Rapid 12 Minute Cycle: The 134º C without drying cycle takes only 12 minutes. Three other cycles are available 134ºC with drying and 121º C with and without drying. Time includes condensing. Choice of Chamber Size: Chambers are 20cm in diameter and available in two lengths, standard (35cm) and long (50cm).
|
Description: At last, a large diameter chamber that really can process more than a Little Sister 3. Just because an autoclave boasts a large chamber it doesn't mean it can accommodate a larger load. The Little Sister 5 is designed to utilize the whole of the chamber capacity. Its 8 tray/3 cassette capacity can handle
an 8kg maximum load! A host of revolutionary design and performance
features make this the autoclave of choice for the new millennium. Design: The revolutionary design removes all unnecessary pipe work and moving parts providing the highest standard of reliability and serviceability.
Choice:
Safety & Versatile: This unit is versatile and incorporates a complete range of safety features.
|
Description: The Little Sister Washer Disinfector uses high temperatures and detergents to effectively decontaminate instruments without the use of harmful chemicals, which can damage instruments and equipment, and pose potential hazards to users. The Little Sister Washer Disinfector is available in 2 widths, 60cm as standard or a slimline 45cm version. Both models have a high-grade stainless steel finish inside and spray arms to ensure full coverage and effective cleaning of all surfaces. The units are designed to use modern non-aggressive detergents/chemicals. Unique adapters are available to enable the cleaning of hollow instruments such as trocars and dental hand pieces. Water is forced through the lumens to ensure all debris, blood and fluids are removed from the internal recesses of these instruments. Once the washer disinfector process is complete, instruments can be placed directly into the SES Little Sister autoclave for sterilization. In using this combination of specialized equipment, together with independent steam penetration test packs, you are assured your instruments are sterile, free from debris and safe for use on patients within your practice.
|
Description: The Little Sister QuickVac is for the sterilization of unwrapped instruments, wrapped and narrow lumen items including hollow instruments for immediate use. Use: Users should refer to device manufacturer's instruction for sterilization, MDA DB 2002(06) and conduct performance qualification tests for each type of load to be processed. Instrumentation: LED alphanumeric display provides machine status, cycle status and cycle parameters. Safety: Pressure safety valve, door safety catch, error/warning display, overheat protection door interlock switch, solenoid pressure door lock and built-in air detection system on the Vacuum autoclave. A daily steam penetration test, in accordance with the requirements of MDA DB 2002(06), is available. State of the art software controls all parameters guaranteeing sterilization. RS232 port for PC interface for calibration, diagnostics and cycle history. Micro-bacterial filter. Design: The revolutionary design removes all unnecessary pipe work and moving parts providing the highest standard of reliability and serviceability. Lightweight and easy to clean. Chamber and heater have a lifetime guarantee. All servicing, calibration and testing can be conducted through the front of the autoclave, reducing the need for lifting or removing of covers and reducing servicing time and costs. Recyclable material used. Easy to fill, drain and change door seal. Choice: Vacuum technology enables you to confidently sterilize hollow instruments and wrapped items. Rapid drying and extendable drying. Cycle acceleration to speed up condense times. Printer guaranteeing print cycle history and printer test. Special programs for testing.
|
For assistance call 1- 800-801-9934 and ask for
Andrea, Renata, Ed, Shlomo, or Chuck
Contact Us
Find an autoclave or sterilizer that will sterilize all instruments. COX dry heat sterilizer, Pelton and Crane OCM, OCR; Distributors of Sterilizers & Autoclaves. |