Affiliates Alfa's Profile Blog Become an Authorized Service in your area Home International Sterilizer repairs Local service near you Parts Explosions Replace your sterilizer Site Map Store Support Technical Help Testimonials Ultrasonic Cleaner What Sterilizer shall I get? Disclaimer Privacy Policy Cancellation / Refund / Return My Account

 

Alfa Medical
10 Bond St
Great Neck NY 11021
Contact us





Alfa Medical Equipment Specialists Inc. BBB Business Review


Ozone Sterilizer: Bed Bugs Solution, Bed Sterilizer

Ozone Sterilizer Aqua Ozone Sterilizer CE Certificate



Bed Before Sterilizing

Pillow

Bed Sheet

Bed Bugs Solution

OPERATION DIRECTION


* Put the mattresses, bed clothes, bed sheets, pillows, etc. into the sealed plastic sterilization bags and then connect the gas transport pipes.
* Turn on the power button ON. Then choose the sterilizating time. Last, press the thin film switch ON, and then the equipment would begin to work. Count down the time, and when the clock reaches 00, the disinfecting operation has finished.
* After finishing the sterilizing operation, the equipment would ring. After that, take off the gas transport pipes. The whole sterilization is finished. Manual Operation
* After main switch on, the Default operation is manual,and the light of channel 1 is on, which shows “18” on the display.
* Press“Selection channels ” to choose the required channels,and the relevant lights will be on. 1. Light 1 is on, indicating channel 1 is switched on. 2. Light 2 is on, indicating channel 1 and channel 2 are switched on. 3. Light 3 is on, indicating channel 1,channel 2,and channel 3 are switched on.
* After choosed the required channels, press the relevant thin film switch “ON”. It will enter into the whole sterilization procedure. The progressing time of each stage is Default. The Default as following:
1. 1 channel is switched on. Vaccum: 5 min Ozone generating: 18 min Ozone-maintain: 20 min Ozone decomposition: 6 min 2. 2 channels are switched on. Vaccum: 8 min Ozone generating: 25 min Ozone-maintain: 20 min Ozone decomposition: 9 min 3. 3 channels are switched on. Vaccum: 10 min Ozone generating: 30 min Ozone-maintain: 20 min Ozone decomposition: 12 min 6

NOTES:


* If you are not satisfied with the Default Ozone generating time, you could adjust time (1-99 min) by press the relevant“ ”, before switch “ON” on thin film.
* After switch “ON”, it shows TIME and SIGN of each stage by turns. The precedure and sign of each stage is as following: Vaccum (CC)
* Ozone generating (O3)
* Ozone-maintain (OF)
*Ozone decomposition (O2)
* OVER (OP).
* The procedure could be stopped when vaccum by switch “OFF”,otherwise,in other stages, any press on thin film will be no function.
* It shows “ OP” when whole procedure is completed and buzz 3 times at the same time.After,Turn off the main switch. Attention:
* The device complete sterilization or stopped by man force,if need continue sterilzation, you have to turn off the main switch,and switch on again, otherwise, it will be no fuction.
* If device enter into ozone generating stage, all the key on thin film will be no function. If want to stop the procedure by force,you have to turn off the main switch. Auto Operation Modo 1 is suitable for hospital uses, while Modo 2 is suitable for hotel uses. ? After main switch on, the Default operation is manual,and the light of channel 1 is on, which shows “18” on the display. ? Press “Mode Auto Select 3 Channels” to switch into auto procedure,then you could switch on Modo 1 or Modo 2, which the relevant light will be on and all the channels are switch on. The device will start to enter into procedure. The Default time is as following: 1. Modo 1 Vaccum: 10 min Ozone generating: 30 min Ozone-maintain: 10 min Ozone decomposition: 20 min The whole sterilzation time is 70 min. 7 2. Modo 2 Vaccum: 10 min Ozone generating: 25 min Ozone-maintain: 10 min Ozone decomposition: 15 min The whole sterilzation time is 60 min. NOTES:
* After start, it shows TIME and SIGN of each stage by turns. The precedure and sign of each stage is as following: Vaccum (CC)
* Ozone generating (O3)
* Ozone-maintain (OF)
*Ozone decomposition (O2)
* OVER (OP).
* During the auto mode procedure, any press on thin film will be no function.
* It shows “ OP” when whole procedure is completed and buzz 3 times at the same time.After,Turn off the main switch.

Bed Sterilizer Manual

Bed Sterilizer Catalog

Bed Sterilizer CE Certificate

 