Affiliates Alfa's Profile Blog Become an Authorized Service in your area Home International Sterilizer repairs Local service near you Parts Explosions Replace your sterilizer Site Map Store Support Technical Help Testimonials Ultrasonic Cleaner What Sterilizer shall I get? Disclaimer Privacy Policy Cancellation / Refund / Return My Account

 

Alfa Medical
10 Bond St
Great Neck NY 11021
Contact us





Alfa Medical Equipment Specialists Inc. BBB Business Review


Bio-Logic™ Product Overview
- 1.5 or 3.0 gallons per minute [gpm], 90 or 720 gallons per hour [gph]
- Potable and high purity water applications
- 316 Stainless Steel, electropolished and passivated inside and out
- Dual heads may be removed and rotated for versatility during installation
- Easy Off
™ Retainer Cap for effortless lamp change
- Fused quartz sleeve insure optimum lamp output at normal potable water temperature
BioLogic™
Pure Water Pack
™
Product Overview

- The BioLogic
™ 1.5 gallons per minute [gpm], 90 gallons per hour [gph] UV Water Purifier

- The Pure Water Pack
™
Dual filter housing includes sturdy 5 micron sediment
filter which removes dirt,
rust, scale, silt and sand, while the other 5 micron carbon filter removes
chlorine, THM's, pesticides and other volatile organic hydrocarbons

- Installation kit and mounting brackets included
Bio-Logic™ & Bio-Logic™ Pure Water Pack™ Product Advantages




 

 

Effective - virtually all microorganisms are susceptible to Bio-Logic™ disinfection.
Economical - hundreds of gallons are purified for each penny of operating cost.
Safe - no danger of overdosing, no addition of chemicals.
Chemical Free - no chlorine taste or corrosion problems.
Fast
- water is ready for use as soon as it leaves the purifier – no further contact time required.
Easy - simple installation and maintenance. Compact units require minimum space.
Automatic - provides continuous disinfection without special attention or measurement.


Efficient - water is passed through a sediment filter and a carbon filter before the ultraviolet disinfection process.
Bio-Logic™ Ultraviolet Purifier Features

Construction
The Bio-Logic
™ chamber is constructed of type 316 stainless steel and is electropolished and passivated for an attractive finish and dependable service.


Dual Heads
Constructed of type 316 stainless steel, heads may be removed and rotated and individually oriented for versatility during installation.

Quick Lamp Change
Exclusive Easy-Off™ Retainer Cap enables effortless lamp replacement without shut down of water pressure or drainage of tank. No tools required.

Fused Quartz Sleeve
Insures optimum lamp output at normal potable water temperature.

Bio-Logic™ Pure Water Pack™  Additional Product Features
Dual Filter Housing
Sturdy, 5 micron sediment filter cartridge removes dirt, rust, scale, silt, sand and other water suspended particles while the 5 micron carbon filter removes chlorine, THM's, pesticides and other related volatile organic hydrocarbons.

Installation Kit
Includes everything necessary to hook up entire system - tubing, saddle valve (saddle valve fits feed pipes between 3/8" to 1/2") and long reach faucet.

Mounting Bracket
Stainless steel bracket with all system components factory installed. Unit is ready for hook up under the sink as soon as it’s removed from carton.
Bio-Logic™ Ultraviolet Purifier & Bio-Logic™ Pure Water Pack Photos

Bio-Logic™ Models BIO-1.5 [1.5GPM/90GPH]
Bio-Logic™ Models BIO-1.5 [1.5GPM/90GPH] & Pure Water Pack™, valve & faucet
Bio-Logic™ Models BIO-1.5 [1.5GPM/90GPH] & Pure Water Pack™, on stand for demo
Bio-Logic™ Ultraviolet Purifier Principle of Operation

The Bio-Logic™ has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber.

1. Filtered water enters the ultraviolet purifier and flows into the annular space between the quartz sleeve and the chamber wall.

2. Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp

3. The LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation.

4. Water leaving the purifier is ready for use, no further contact time is required.
Bio-Logic™ Pure Water Pack™ Principle of Operation
The Bio-Logic™ Pure Water Pack™ has been designed to provide adequate filtering and germicidal ultraviolet dosage.

1. Water enters the sediment filter and traps the particulates, rust, scale and residue that affect the taste and appearance of water supply.

2. Water continues into the carbon filter and reduces chlorine, unpleasant tastes, odors and other organic chemicals and
turbidity.

3. Filtered water enters the ultraviolet purifier and flows into the annular space between the quartz sleeve and the chamber wall.

4. Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp

5. Water leaving the purifier is ready for use, no further contact time is required.
Bio-Logic™ Ultraviolet Purifier Residential Models

BIO-1.5
Flow Rate 1.5 gpm
Voltage 120v
60 Hz
220v
50/60 Hz
12v DC
Current (Amps) .24 .125 1.27
Unit Dimensions 14-1/2"(L) x 3-11/16"(W)
x 3-7/8"(H)
Shipping Wt. 8 lbs.
Rated Water Pressure Maximum PSI 125
BIO-3.0
Flow Rate 3 gpm
Voltage 120v
60 Hz
220v
50/60 Hz
12v DC
Current (Amps) .33 .17 1.67
Unit Dimensions 20-1/8"(L) x 3-11/16"(W)
x 3-7/8"(H)
Shipping Wt. 9 lbs.
Rated Water Pressure Maximum PSI 125
Bio-Logic™ Pure Water Pack™ Residential Model
BIO-1.5 & Pure Water Pack™
Flow Rate 1.5 gpm
Voltage 120v
60 Hz
220v
50/60 Hz
12v DC
Current (Amps) .24 .125 1.27
Unit Dimensions 15"(L) x 5-5/8"(W)
x 17-1/2"(H)
Shipping Wt. 18 lbs.
Rated Water Pressure Maximum PSI 125
Bio-Logic™ Ultraviolet Purifier Water Quality Recommendation
Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended hat the water does not exceed the following maximum concentration levels:

Manganese:

0.05 mg/L

Total Suspended Solids:

10 mg/L

pH:

6.5 - 9.5

Color:

None

Hardness:

6 gpg or 102.6PPM

Iron:

0.3 mg/L
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the ultraviolet transmission is not satisfactory, contact the factory.
Bio-Logic™ Ultraviolet Purifier Standard Model Germicidal Lamp Data
Lamp No. Model No. Nominal Lamp Length Power Consumption [Watts]
(1)
UV Output [Watts] (2) Rated Effective Life [Hrs.]
05-1366 BIO-1.5 11-19/64"
(287mm)
14 3.7 10,000
05-1370 BIO-3.0 17-5/32"
(436mm)
20 6.4 10,000
(1) Wattage is lamp watts only and does not include ballast loss (approximate).
(2) Maximum rated output at 254 nanometers.
The lamps listed above have been especially developed and are recommended for use with Bio-Logic™ Water Purifiers.

All STER-L-RAY™ lamps used in Bio-Logic™ units are low pressure type which afford the maximum efficiency in producing the required germicidal rays. In addition to the obvious advantages of high efficiency and low power requirements, there is no possibility of the unit overheating (as is the case with some other lamp types). Consequently, the need for additional equipment to combat overheating is eliminated.

CAUTION: Exposure to direct or reflected germicidal ultraviolet rays will cause painful eye irritation and reddening of the skin. Personnel subject to such exposure must wear suitable face shield, gloves and protective clothing. Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws.
Bio-Logic™ Ultraviolet Dosage
ORGANISM ALTERNATE NAME TYPE DISEASE Dose*
Bacillus subtilis spores B. subtilis Bacteria ———— 22,000
Bacteriophage Phage Virus ———— 6,600
Coxsackie virus ———— Virus Intestinal Infection 6,300
Shigella spores ———— Bacteria Bacterial Dysentery 4,200
Escherichia coli E. coli Bacteria Food Poisoning 6,600
Fecal coliform ———— Bacteria Intestinal Infection 6,600
Hepatitis A virus Infectious Hepatitis virus Virus Hepatitis of the Liver 8,000
Influenza virus Flu virus Virus Influenza 6,600
Legionella pneumophila ———— Bacteria Legionnaires’ Disease 12,300
Salmonella typhi ———— Bacteria Typhoid Fever 7,000
Staphylococcus aureus Staph Bacteria Food Poisoning,
Toxic Shock Syndrome, etc.
6,600
Streptococcus spores  Strep Bacteria Strep Throat 3,800
When used as directed to disinfect clear water, Bio-Logic™ Water Purifiers provide an ultraviolet dosage in excess of 30,000 microwatt seconds per square centimeter (΅WSec/cm2).

* Nominal Ultraviolet dosage (΅WSec/cm2) necessary to inactivate better than 99% of specific microorganism. Consult factory for more complete listing.

Bio-Logic™ Installation & Maintenance

-The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels.
-Ordinary maintenance consists of the cleaning of the quartz sleeve, when conditions warrant.
-Lamp replacement is recommended every 10,000 hours of operation (approximately 12 months of continuous service).

Bio-Logic™ & Pure Water Pack™ Installation & Maintenance

-The Pure Water Pack is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels.
-Filter cartridge replacement is recommended every 12 months. Over time water pressure to the system faucet will drop, this is an indication that the filter cartridges are nearing the end of their service life.
-In poor quality water supplies filter cartridges may clog more rapidly, before the 12 months are up, reducing water pressure to the system faucet. In these cases, change filter cartridges immediately. Changing filter cartridges will restore normal water pressure.
-Lamp replacement is recommended every 10,000 hours of operation (approximately 12 months of continuous service).
-Cleaning of the quartz sleeve, when conditions warrant.

Bio-Logic™ Installation Photo of Demo Unit
Bio-Logic™ Optional Accessories








 

The SENTRY™ safety sensor provides constant monitoring of the water purifier's ballast and germicidal lamp operation; indicator lights provide constant visual indication of ballast and germicidal lamp status.
• Easy installation,
• Plug SENTRY™ into an electrical outlet, then plug water purifier into SENTRY™
• Operates optional Solenoid Valve and Audio Alarm
• Warns of lamp failure
• Easily adaptable for use with other water purifier brands.
• Available in 120v 50/60 Hz or 220-240v 50/60 Hz
• Available for use with models up to 20 gpm


 

 

 

The STERALERT™ lamp status alarm monitors visible light emitted through the sight port plug of the water purifier and activates an audible alarm when visible light falls below acceptable levels.
• Easy installation, no tools
• Mounts on the sight port plug
• Warns of lamp or power failure
• Produces a high frequency tone pulse at two to three cycles per second
• Monitors visible light only; does not monitor ultraviolet intensity
• Operates on a 9v battery or optional 120v 60Hz Power Adapter, specify when ordering
• Available for use with all models

Audio Alarm Activated by the Sentry™ or Guardian™ - alerts user to any malfunction detected.

Time Delay Mechanism
Provides a 2-minute
warm-up period for lamp
to achieve full germicidal
output.

Elapsed Time Indicator
Real-time, non-resettable
display of accumulated
operating hours.

Solenoid Valves
Operates with the Sentry™ and prevents flow during detected malfunctions. Available in nylon or brass.
Flow Control Valves
Limits water flow to rated capacities. Available in PVC and stainless steel.