HG-50 With
Innovative Feature… |
Automatic lid opening button replaces a foot pedal. Automatic lid closing button closes and locks lid conveniently and safely. New body design with a 80-liter chamber of larger diameter and shorter height. Safety interlock senses pressure and temperature and prevents lid from opening when the chamber is pressurized, temperature is too high, and also during a cycle. Programmable auto-start for running a cycle up to 99 hours later. Large and efficient steam condenser eliminates steam exhaust into the lab. Over-flow lamp indicates that the drain bottle is full and ready to be emptied. Built-in cooling fan for faster post-sterilization cooling and shorter completion time. Selectable rate of steam venting after sterilization. Programmable time for air removal before sterilization. Large control and display panel improves functionality and shows the progress of the sterilization cycle: |
SPECIFICATIONS OF HG-50 AUTOCLAVE
|
HG-50 | ||
Outside Dimensions |
(19.7W x 27.2D x 35.0H) in |
| |
Chamber Dimensions |
(14.3D x 28.7H) in, | ||
Chamber Volume | |||
Temperature Range |
105°C to 135°C | ||
Sterilization Timer | 1 to 300 minutes | ||
Media Warming/ Holding Temperature | Programmable at 45°C to 60°C to keep media warm up to 24 hours | ||
Auto-Start Timer |
Initiate a cycle 1 to 99 hours later | ||
Cooling Fan | Switch to turn fan on or off | ||
Air Removal Timer | Programmable, 3 to 9 minutes after temperature has reached 97°C | ||
Steam Venting |
Selectable from: No venting and three other venting rates | ||
Temperature for Release of Lid Interlock | Programmable, 60°C to 97°C for greater safety and flexibility | ||
Sterilization Program Cycles |
1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle | ||
Additional Cycle for Agar Dissolution | Cycle for dissolving and keeping agar warm (no sterilization) | ||
Agar Dissolution Protocol |
Initially at 60°C-100°C for 1-60 min, then at 45°C-60°C for up to 24 hours. | ||
Safety Features | Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve (0.26MPa gauge), sensor for improper lid closing | ||
Steam Condenser |
15-liter water tank | ||
Drain Water Bottle | 2 liters | ||
Power Requirements |
220V, 50/60 Hz, single phase | ||
Power Consumption | 3.7 kilowatts |
Autoclave
Accessories
Three different types of stainless steel containers of
different heights (large, medium and small) are available for handling different
loads. Stacking shorter containers can increase load capacity (two medium-sized
and three small-sized containers can fit in a given chamber). A mesh wire basket
is suitable for most loads, including glassware and media. A pail is used for
media and Petri dishes with liquid in them as well as to contain potential spillage
from waste bags. A drum has a hinged lid with a handle. Depending on the load,
it serves as a closed (but not watertight) trash container or as a carrying and
storage case. The side and bottom of the drum are perforated for better steam
penetration. Sliding panels cover these perforations prior to and after sterilization.
Two round stainless steel tube racks, either with capacity for sixty 20-mm or
ninety 13-mm tubes per rack, are also available. You can stack the tube racks
by putting them inside the accessory containers.