Portable, Top-loading Autoclaves With Advanced Safety and User-Friendly Features
Space-saving design with lid opening upward. Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C. Automatic air purging by a microprocessor prevents over-pressurization during a cycle. One-touch lever to easily open and close chamber lidProgrammable rate of steam exhaust. Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly.In-process display shows status and progress of sterilization cycle. Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature.Unique
accessory: Floating sensor to monitor load temperature.
Sterilization timer is
activated only when load temperature reaches set temperature. Memory backup system retains user-programmed parameters even in case of power failure. |
Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). |
Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). |
Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). |
Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). |
Models HV-25 and HV-50 Specifications |
MODEL | HV-25 | HV-50 |
TEMPERATURE | ||
Operating Range | 105ºC to 126ºC | 105ºC to 135ºC |
Display Range | 128ºC | 137ºC |
Warming Range | 45ºC to 60ºC | |
Agar Dissolution | Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. | |
GAUGE PRESSURE | ||
Operating Range | 3 to 22 psi gauge (0.02 to 148 MPa) | 3 to 30 psi (0.02 to 0.206 MPa) |
Maximum Allowable | 27 psi (0.186MPa) | 38 psi (0.26MPa) |
TIMER | ||
Sterilization | 1 to 250 minutes | |
Delayed Auto-start | Program autoclave to start 1 minute to 7 days later | |
DIMENSIONS | ||
Overall (W x D x H) | (19
x 18 x 37.4) in (48 x 46 x 95) cm |
(20
x 21 x 41) in (51 x 53 x 104) cm |
Chamber (Diameter x Height) |
25
liters 9.4" x 21.6" (24 cm x 55 cm) |
50
liters 11.8" x 28" (30 cm x 71 cm) |
SAFETY DEVICES | Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker | |
PROGRAMS | ||
1. For agar | Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion | |
2. For liquids | Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion | |
3. For solids | Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion | |
4.
For melting agar or for faster start-up |
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion | |
ACCESSORIES | ||
Stainless steel | Mesh wire baskets, buckets (pails), and round tube racks | |
Factory or field installed | Floating sensor, auto water supply unit, and digital printer | |
POWER | ||
Source | 120V, 50/60 Hz (220V/240V available) | |
Consumption | 1500 watts (1500VA) | 2000 watts (2000VA) |
SHIPPING WEIGHT | 160 lb (73 kg) | 180 lb (82 kg) |
Models HV-85 and HV-110 Specifications |
MODEL | HV-85 | HV-110 |
TEMPERATURE | ||
Operating Range | 105ºC to 135ºC | |
Display Range | 137ºC | |
Warming Range | 45ºC to 60ºC | |
Agar Dissolution | Heating at 60ºC to 100ºC for up to 1 hour (temp. and time programmable), followed by 45ºC to 60ºC (temp. programmable) for up to 20 hours. | |
GAUGE PRESSURE | ||
Operating Range | 3 to 30 psi (gauge), 0.021 to 0.21MPa | |
Maximum Allowable |
38 psi (gauge), 0.26MPa | |
TIMER | ||
Sterilization | 1 to 250 minutes | |
Delayed Auto-start | Program autoclave to start 1 minute to 7 days later | |
DIMENSIONS | ||
Overall (W x D x H) | (26
x 25.6 x 39.4) in (66 x 65 x 100) cm |
(26
x 25.6 x 46.5) in (66 x 65 x 118) cm |
Chamber (Diameter x Height) | 85
liters 16.5" x 24.2" (42 cm x 61.5 cm) |
110
liters 16.5" x 31.3" (42 cm x 79.5 cm) |
SAFETY DEVICES | Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker | |
PROGRAMS | ||
1. For agar | Heating -> Sterilization -> Exhaust (slow, programmable) -> Warming -> Completion | |
2. For liquids | Heating -> Sterilization -> Exhaust (slow, programmable) -> Completion | |
3. For solids | Heating -> Sterilization -> Exhaust (fast, programmable) -> Completion | |
4.
For melting agar or for faster start-up |
Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion | |
ACCESSORIES | ||
Stainless steel | Mesh wire baskets, buckets (pails), and tube rack | |
Factory or field installed | Floating (load) sensor, auto water supply unit and digital printer | |
POWER | ||
Source | 208V/220V/240V, 50/60 Hz, single phase | |
Consumption | 3000 watts (3000VA) | 4000 watts (4000VA) |
SHIPPING WEIGHT | 282 lb (128 kg) | 308 lb (140 kg) |