Affiliates Alfa's Profile Blog Become an Authorized Service in your area Home International Sterilizer repairs Local service near you Parts Explosions Replace your sterilizer Site Map Store Support Technical Help Testimonials Ultrasonic Cleaner What Sterilizer shall I get? Disclaimer Privacy Policy Cancellation / Refund / Return My Account

 

Alfa Medical
10 Bond St
Great Neck NY 11021
Contact us





Alfa Medical Equipment Specialists Inc. BBB Business Review



LD Series
  photo
Click Here for Larger View

Interscan's LD Series represents the ultimate in single point continuous monitoring systems. Each and every component has been chosen based on years of experience in some of the most demanding environments imaginable. What's more, the units are easy and inexpensive to maintain.

An impressive array of options allows the specifier to put together a system ideally suited to the application at hand.

 

Options

  • Alternative packaging, including Type X or Type Z purged enclosures and RFI resistant enclosures

  • Audible alarm

  • Visual alarm

  • Enclosure heating and cooling

  • Loss of flow alarm

  • Triple alarm set points

  • Loss of power alarm

  • Aspirator (in lieu of pump)

  • Auto zero

  • Sensor protection circuit
 

Features

  • Super-rugged NEMA Type 4X fiberglass reinforced polyester enclosure

  • 3½ digit LED display

  • Integral diaphragm pump

  • Rotameter

  • Analog output---
      0-100 mV & 4-20 mA full scale

  • Low and high alarm contacts, continuously adjustable through the full scale measuring range, activating dedicated relays

Additional Specs

Resolution
0-1999 ppm range:  1 ppm
0-199.9 ppm range:  0.1ppm
0-19.99 ppm range:  0.01 ppm

Weight:
22 lb (10.0 kg)

Dimensions:
22" H x 18" W x 8.5" D
(559 x 457x 216 mm)

Specifications common to all Interscan gas detection instruments

 

RM Series
 
photo

Interscan's Rack-Mount configured analyzers are intended for those applications in which line power operation is desired (allowing continuous operation and the incorporation of heavier-duty alarm signals or alarm contacts), but in which the rigorous NEMA 4X packaging of the LD Series is not required.

Designed to be installed in a standard 19 inch (483 mm) rack or to be used on the bench, their open frame construction and use of standard electrical and pneumatic components allow easy incorporation of the units into a system. Many of the LD Series' features and options are available.

 

Options

  • Integral pump

  • Rotameter

  • Loss of flow alarm

  • 4-20 mA analog ouput

  • Alarm contacts

  • Dual alarm set points

  • Triple alarm set points

  • Loss of power alarm

  • Slide rail hardware and accesss door, for rack mounting

 

Features

  • 3½ digit LED display

  • Wrap-around cover

  • 0-100 mV analog output

Additional Specs

Resolution
0-1999 ppm range:  1 ppm
0-199.9 ppm range:  0.1ppm
0-19.99 ppm range:  0.01 ppm

Weight:
8 lb (3.6 kg)

Dimensions:
7" H x 19" W x 12" D
(178 x 483 x 305 mm)

Specifications common to all Interscan gas detection instruments

 

Ordering Information:
LD Series Continuous Monitoring Systems and
RM Series Rack Mount Analyzers

GAS

MEASURING
RANGE (ppm)

LD SERIES Model No.

RM SERIES Model No.

LOWEST RANGE
Available on special order (ppm, unless otherwise indicated)
Br2
bromine
0-1999
0-199.9
0-19.99
LD70-0
LD70-1
LD70-2
RM70-0
RM70-1
RM70-2
0-5
CO
carbon monoxide
0-1999
0-199.9
LD14-0
LD14-1
RM14-0
RM14-1
0-19.99
Cl2
chlorine
0-1999
0-199.9
0-19.99
LD34-0
LD34-1
LD34-2
RM34-0
RM34-1
RM34-2
0-5
ClO2
chlorine dioxide
0-1999
0-199.9
0-19.99
LD33-0
LD33-1
LD33-2
RM33-0
RM33-1
RM33-2
0-1999 ppb
C2H4
ethylene
0-1999
0-199.9
0-19.99
LD07-0
LD07-1
LD07-2
RM07-0
RM07-1
RM07-2
0-5
EtO
ethylene oxide
0-1999
0-50.0
0-19.99
LD20-0
LD20-1
LD20-2
RM20-0
RM20-1
RM20-2
0-5
HCHO
formaldehyde
0-1999
0-199.9
0-19.99
LD16-0
LD16-1
LD16-2
RM16-0
RM16-1
RM16-2
0-1999 ppb
H2NNH2
CH3NHNH2
(CH3)2NNH2
hydrazine(s) ¶
0-1999
0-199.9
0-19.99
LD18-0
LD18-1
LD18-2
RM18-0
RM18-1
RM18-2
0-1999 ppb
H2
hydrogen
0-1999
0-199.9
0-19.99
LD02-0
LD02-1
LD02-2
RM02-0
RM02-1
RM02-2
0-200
HBr
hydrogen bromide
0-1999
0-199.9
0-19.99
LD80-0
LD80-1
LD80-2
RM80-0
RM80-1
RM80-2
0-5
HCl
hydrogen chloride
0-1999
0-199.9
0-19.99
LD36-0
LD36-1
LD36-2
RM36-0
RM36-1
RM36-2
0-5
HCN
hydrogen cyanide
0-1999
0-199.9
0-19.99
LD28-0
LD28-1
LD28-2
RM28-0
RM28-1
RM28-2
0-5
H2S
hydrogen sulfide
0-1999
0-199.9
0-19.99
LD17-0
LD17-1
LD17-2
RM17-0
RM17-1
RM17-2
0-1000 ppb
NO
nitric oxide
0-1999
0-199.9
0-19.99
LD54-0
LD54-1
LD54-2
RM54-0
RM54-1
RM54-2
0-5
NO2
nitrogen dioxide

Also known as N2O4
nitrogen tetroxide
0-1999
0-199.9
0-19.99
LD15-0
LD15-1
LD15-2
RM15-0
RM15-1
RM15-2
0-5
O3
ozone
0-1999
0-199.9
0-19.99
LD48-0
LD48-1
LD48-2
RM48-0
RM48-1
RM48-2
0-5
PrO
propylene oxide
0-1999
0-199.9
0-19.99
LD32-0
LD32-1
LD32-2
RM32-0
RM32-1
RM32-2
0-5
SO2
sulfur dioxide
0-1999
0-199.9
0-19.99
LD24-0
LD24-1
LD24-2
RM24-0
RM24-1
RM24-2
0-5