Sterilizers and autoclave available for all needs.
Steam new Steam refurbished Dry Heats Repairs Parts
800-801-9934
Affiliates Alfa's Profile Blog Become an Authorized Service in your area Home International Sterilizer repairs Local service near you Parts Explosions Replace your sterilizer Site Map Store Support Technical Help Testimonials Ultrasonic Cleaner What Sterilizer shall I get? Disclaimer Privacy Policy Cancellation / Refund / Return My Account

 

Alfa Medical
10 Bond St
Great Neck NY 11021
Contact us





Alfa Medical Equipment Specialists Inc. BBB Business Review


MBA Electric Steam Generator

mba

Small size, small capacity Sussman MBA Electric Steam Generators are perfect for applications requiring efficient, high quality steam in laboratories, hospitals, pilot plants and for small, intermittent, low-steam consuming loads.

These generators can be used for standby operations in off-seasons or when a larger boiler is shut down or unavailable. The automatic electronic liquid level controller meets all UL and ASME requirements. A main waterline pressure 10 psig greater than the operating pressure of the steam generator is required for automatic water feeding.

All MBA steam generators are factory tested and are ready to operate.

SUSSMAN MBA Series Features:

  • Safe easy-to-use heat source - no on-site products of combustion.
  • Easy and quick to install, they require only a water feed connection and electrical hook-up.
  • Steam available at the flip of a switch.
  • Applications include: Laboratory use, steam for small tanks, reactions and distillations, autoclaves, food products, jacketed vessels for processing waxes, paraffins, glues, resins and varnishes and woodbending.
  • Built in accordance with Section I Code M of ASME Boiler and Pressure Vessel Codes,to 100PSIG trim.
  • UL Listed and CSA Certified.

STANDARD FEATURES

  • LIQUID LEVEL / LOW WATER CONTROL
    The electronic control automatically maintains proper water level, and shuts off the generator when water supply in the boiler drops below a safe operating level.
  • WATER LEVEL SIGHT GLASS
    Allows constant observation of water level while boiler is in operation
  • ON-OFF SWITCH
    Complete with pilot light, for switching the generator on and off.
  • INTEGRAL ELECTRICAL CONTROL
    Magnetic contactor energizes the element and is integrally mounted in the control unit.
  • BLOWDOWN/DRAIN VALVE
    Facilitates emptying the pressure vessel during blowdown/ drain sequence.
  • STEAM OUTLET VALVE
    Provides easy control of steam.
  • LONG LIFE HEATING ELEMENTS
    Industrial grade, heavy duty stainless steel heating elements equipped with one piece resistance welded terminations for added strength and safety.
  • OPERATING PRESSURE CONTROL
    Operates automatically to maintain steam pressure within generator.
  • MANUAL RESET PRESSURE CONTROL
    Provides high limit pressure cut-out with manual reset.
  • STEAM SAFETY VALVE
    ASME Code valve, automatically opens to reduce pressure should excessive steam cause pressure build-up.
  • STEAM PRESSURE GAUGE
    Allows visual observation of steam pressure over full range.
  • ENERGY SAVING AND MINIMUM MAINTENANCE
    Fully insulated pressure vessel minimizes heat loss and maximizes energy savings.
  • EASY CONTROL MAINTENANCE
    All controls and components are easily accessible. Fully-louvered openings avoid component heat build-up.
  • RUGGED CONSTRUCTION
    Performance is insured for all typical industrial applications.

MEETING CODE REQUIREMENTS

  • Pressure vessel rated at 100 psig to ASME Section I, Code M and National Board registered.
  • UL listed, CSA certified, built to NEC.
  • All units are physically identical and have a packed shipping weight of 125LBS.
  • Units are trimmed at 100PSIG as standard. Lower trims are available.
  • Incoming water line pressure must be 10 PSIG greater than generator operating pressure. If not, a motor/pump must be used. Specify Sussman 38002A high pressure feedwater motor/pump system.
  • When ordering: Specify Model No., KW, volts/ph and motor/pump, if required.
  • Water Connection is 1/4 NPT. Steam outlet is 1/2 NPT.
MBA Electric Steam Generator Specifications

mba2

DIMENSIONAL INFORMATION
SYMBOL
INCHES
A
20 1/2
B
17 1/2
C
17 7/8
D
15 3/4

MODEL
KW
VOLTS
PH
AMPS
PPH
MBA3A1
3
120
1
25
9
MBA3B1
3
208
1
15
9
MBA3C1
3
240
1
13
9
MBA6B1
6
208
3
17
18
MBA6C1
6
240
3
15
18
MBA6F1
6
480
3
8
18
MBA9B1
9
208
3
25
27
MBA9C1
9
240
3
22
27
MBA9F1
9
480
3
11
27
MBA12B1
12
208
3
34
36
MBA12C1
12
240
3
29
36
MBA12F1
12
480
3
15
36
MBA18B1
18
208
3
50
54
MBA18C1
18
240
3
44
54
MBA18F1
18
480
3
22
54
MBA20B1
20
208
3
56
60
MBA20C1
20
240
3
49
60
MBA20F1
20
480
3
25
60

SYMBOL
DESCRIPTION
1
STRAINER
2
WATER SOLENOID
3
CHECK VALVE
4
DRAIN VALVE
5
STEAM OUTLET W/STEAM VALVE
6
GAUGE GLASS ASSEMBLY
7
SAFETY VALVE
8
PRESSURE GAUGE
9
HI-LIMIT PRESSURE CONTROL
10
OPERATING PRESSURE CONTROL
11
ACCESS PANEL
12
ON/OFF SWITCH

1. All units are physically identical and have a packed shipping weight of 125 LBS.
2. Units are trimmed at 100 PSIG as standard . Lower trims are available.
3. Incoming water line pressure must be 10 PSIG greater than generator operating pressure. If not, a motor/pump must be used. Specify Sussman 38002A high pressure feedwater motor/pump system.
4. When ordering: Specify Model No., KW, volts/ph and motor/pump, if required.
5. Water connection is 1/4 NPT. Steam outlet is 1/2 NPT.

Sussman ES Packaged Electric Steam Boilers


es

Suitable for industries requiring efficient, high quality saturated steam, including laboratories, hospitals, industrial plants, pilot plants, food and chemical processing applications.

These versatile generators are perfect for almost any application requiring steam from 0-150 PSIG. Each unit is complete with automatic features, including pressure and liquid level controllers, ASME Code pressure vessel and safety valve and are fully tested under power. Each one must pass Sussman's rigid quality control inspection before it is shipped.

Sussman Electric Boilers - your source for fast economical steam energy.

ES SERIES FEATURES:

  • Safe easy -to-use heat source - No on-site products of combustion.
  • Easy, quick to install, they require only a water feed connection and electrical hook-up.
  • Applications include: Steam for tanks, reactors, distillations, autoclaves, dyestuffs, food products, cosmetics, paraffins, glues, resins, varnishes, sterilizers, pipe tracing and humidification.
  • Built to Section I, of ASME Boiler and Pressure Vessel Codes - UL listed and CSA certified.

STANDARD FEATURES:

  • LOW WATER CUT-OFF/LEVEL CONTROL
    A McDonnell Miller #150 control automatically maintains proper water level, shutting off the boiler when water supply in the boiler drops below a safe operating level.
  • WATER LEVEL SIGHT GLASS
    Allows constant observation of water level while boiler is in operation
  • MAIN ON/OFF SWITCH
    Allows manual operation of the boiler operation control circuit.
  • PILOT LIGHT
    Indicates the boiler's on/off condition.
  • INTEGRAL POWER CONTACTORS
    Magnetic contactors for energizing the boiler elements. Integrally mounted in the control unit.
  • BLOWDOWN/DRAIN VALVES
    Facilitates emptying the boiler pressure vessel and MM150 water column piping during blowdown sequence.
  • LONG LIFE HEATING ELEMENTS
    Industrial grade. heavy duty 0.420" diameter stainless steel heating elements equipped with one piece resistance welded terminations for added strength and safety.
  • OPERATING PRESSURE CONTROL
    Resets to maintain preset pressure within boiler.
  • ENERGY SAVINGS AND MINIMUM MAINTENANCE
    Pressure vessel insulation; minimum heat loss and maximum energy savings is insured by fibrous glass material
  • EASY CONTROL MAINTENANCE
    All control panels and components are easily accessible. Fully-louvered openings avoid component heat build-up
  • RUGGED CONSTRUCTION
    Performance is insured for all typical industrial applications.

MEETING CODE REQUIREMENTS

  • Pressure vessel rated at 100 PSIG to ASME Section 1, Code M. Vessel National Board Registered. Sect 1, Code to 150 PSIG rating available.
  • UL Listed. Canadian Standards Association Approved.
  • All electrical construction conforms to NEC standards.

SAFETY FEATURES

  • STEAM SAFETY VALVE
    Automatically opens to reduce pressure should excessive steam cause pressure build-up.
  • STEAM PRESSURE GAUGE
    Allows visual observation of steam pressure over full range
  • MANUAL RESET PRESSURE CONTROL
    Provides high limit pressure cut-out with manual reset.

STANDARD OPTIONAL EQUIPMENT

A complete complement of optional equipment for ES and other Sussman steam boilers is described in Sussman Product Sheet OES. Options covered are water feed systems, condensate returns, progressive sequencers, automatic blowdown systems, blowdown separators and transformers.

ES Packaged Electric Steam Boilers Specifications


es02

Boiler Model
KW
Bhp Rating
Lbs. Steam/Hr. 212 F
††
3 Phase Voltage
Total Amp Draw
Field Wiring Size Power Input Copper 90 C**
Dimensions
Shipping Weight
(Lbs.)
W
L
H
ES-12*
12
1.22
36.2
208
240
480
34
29
15
8
10
14
20
28
36
230
ES-18*
18
1.84
54.2
208
240
480
50
44
22
6
6
10
20
28
36
240
ES-24*
24
2.45
72.3
208
240
480
67
58
29
4
4
10
23
33
44
300
ES-30
30
3.06
90.4
208
240
480
84
73
37
3
4
8
23
33
44
310
ES-36
36
3.67
108
208
240
480
100
87
44
1
2
6
23
33
44
310
ES-48
48
4.90
145
208
240
480
134
116
58
2/0
1/0
4
23
33
44
315
ES-60
60
6.12
181
208
240
480
167
145
73
3/0
2/0
4
23
33
44
380
ES-72
72
7.35
217
208
240
480
200
174
87
250
4/0
2
23
33
44
390
ES-100
102
10.4
307
208
240
480
284
246
123
400
350
1/0
28
34
59
625
ES-135
136
13.9
410
208
240
480
378
328
164
700
600
3/0
30
36
59
785
ES-160
158
16.1
475
240
480
379
190
700
4/0
30
36
61
785
ES-180
180
18.4
542
240
480
434
217
900
250
30
36
61
790
*Single Phase available.
**Lbs/hr steam at 212°F with 50°F feedwater.
***Other voltages available.
****Allow 21" for heating element removal.

For assistance call 1- 800-801-9934 and ask for
Andrea, Renata, Ed, Shlomo, or Chuck

Contact Us